Smart Wearable Research Group, Department of Engineering, Nottingham Trent University, Nottingham NG11 8NS, UK Show
* Author to whom correspondence should be addressed. Signals 2021, 2(3), 392-412; https://doi.org/10.3390/signals2030025 Received: 21 February 2021 / Revised: 18 June 2021 / Accepted: 23 June 2021 / Published: 29 June 2021 (This article belongs to the Special Issue Biomedical Signal Processing for Healthcare Prediction, Diagnosis and Monitoring Tools) Download Download PDF During the pregnancy, fetal electrocardiogram (FECG) is deployed to analyze fetal heart rate (FHR) of the fetus to indicate the growth and health of the fetus to determine any abnormalities and prevent diseases. The fetal electrocardiogram monitoring can be carried out either invasively by placing the electrodes on the scalp of the fetus, involving the skin penetration and the risk of infection, or non-invasively by recording the fetal heart rate signal from the mother’s abdomen through a placement of electrodes deploying portable, wearable devices. Non-invasive fetal electrocardiogram (NIFECG) is an evolving technology in fetal surveillance because of the comfort to the pregnant women and being achieved remotely, specifically in the unprecedented circumstances such as pandemic or COVID-19. Textiles have been at the heart of human technological progress for thousands of years, with textile developments closely tied to key inventions that have shaped societies. The relatively recent invention of smart textiles is set to push boundaries again and has already opened the potential for garments relevant to medicine, and health monitoring. This paper aims to discuss the different technologies and methods used in non-invasive fetal electrocardiogram (NIFECG) monitoring as well as the potential and future research directions of NIFECG in the smart textiles area. Keywords: Electrocardiogram (ECG) can be defined as a graphical representation of bioelectrical signals helpful in determining the functionality of the heart through the analysis of graphic representation obtained during the measurement of cardiac cycle of the person or human body. The aim of the biomedical research is to continuously improve the diagnostic devices and develop non-invasive methods of health monitoring, in addition to upgrading already existing devices, thus reducing the cost involved [,,,,,]. The ongoing research predicts that the main cause of prenatal death is heart defects, as congenital heart defects easily occur during the formation of the heart at the initial stage of pregnancy [,,,]. During the pregnancy, the monitoring of fetal heart rate is essential to identify the proper supply of oxygen, nutrients, and growth of the fetus. Monitoring of the fetus during pregnancy may help in recognizing the pathological conditions, such as fetal hypoxia, allowing prompt medical interventions before irreversible changes taking place. The abnormality in the fetal heart rate of the fetus indicates that there is insufficient oxygen supplied or other problems to the fetus. FHR during pregnancy or labor can be monitored through invasive and non-invasive fetal methods [,] so that the heart functionality of the fetus can be predicted to reflect the growth and wellbeing of the fetus [,,]. Electrocardiography (ECG) was used by researchers in 1906 to invasively determine the FHR through abdominal during the pregnancy [,]. In 1958, Edward H. Hon used the successive R waves method from ECG for the calculation and estimation of FHR non-invasively [,,,,,]. With the advancement in technology, Callagan in 1964 monitored the FHR non-invasively using the doppler sound monitoring procedure, in which an ultrasound beam was sent through the abdomen of the mother and the reflected signal was measured, thus helping to analyze FHR [,,,,]. Unlike invasive fetal electrocardiography (FECG), which involves surgery to insert the electrodes into the scalp of the fetus through the abdomen of pregnant women, non-invasive fetal electrocardiography (NIFECG) deploys electrodes placed on the abdomen of the pregnant mother to extract the fetus’ health information. The electrical signal of the fetal heart rate helps identify the development of the fetus in addition to the presence of any congenital heart disease within the fetus [,,,]. This paper is divided into five sections. provides an overview of fetal electrocardiography (FECG). The different techniques to obtain FECG non-invasively are presented in , where they are critically discussed and compared. The importance of FECG and the electrode configurations for FECG signal extraction are listed in . lists the conclusions, and presents the potential future research directions. Fetal electrocardiogram (FECG) is a biomedical signal, see the example shown in , that provides an electrical representation of fetal heart rate (FHR). It is composed of three parts: (i) the P-wave, (ii) the QRS-complex, which is associated with the contraction of the ventricles, and due to the magnitude of the R-wave it is extremely reliable, and (iii) the T-wave, which corresponds to the repolarization phase and follows each heart contraction [,,,,,]. The delay associated to the R-R interval leads to the heartbeat’s frequency and provides useful information about the heart condition. Morphologies of interest include the shape, size, and duration of individual and groups of FECG waveforms as well as the various ratios relating these quantities to each other [,,,,,,,,,]. The FECG extracted from the maternal electrocardiogram (MECG) is exceedingly small, about 5 times less in amplitude compared to the MECG and is sometimes embedded in the noise signals [,,,,,]. As shown in , the FECG signals are usually buried in noise and artefacts, such as interference noise, muscle contractions, instrumental noise, etc., which easily corrupt the FECG signal [,,]. Therefore, signal processing is essential to remove the noise and artefacts to extract the actual FECG signal to analyze and determine the growth of the fetus []. The fetal heart rate or fetal electrocardiography monitoring thorough abdominal FECG electrodes, i.e., through non-invasive fetal electrocardiogram (NIFECG), has widespread clinical acceptance as it is suitable for long-term recordings without any surgery, unlike invasive FECG. This section illustrates the commonly used fetal heart rate monitoring techniques. This section illustrates the commonly used non-invasive fetal heart rate monitoring techniques in addition to FECG. 3.1. Photoplethysmography (PPG)Photoplethysmography (PPG) is used to measure the fetal heart rate, introduced in 1930. PPG is a non-invasive fetal monitoring procedure which uses changes in blood level volumes to measure FHR [,,,]. The procedure involves the detection of FHR by transmitting a wavelength of 650–950 nm through the maternal abdomen, having a peak wavelength of 890 nm to penetrate the human tissue. The reflected light is analyzed to calculate the fetal heart rate. The example of a PPG signal comprising of both AC and DC components is shown in []. The AC component is the resultant of pulsatile changes in arterial blood volume, whereas the DC component corresponds to the tissues and muscles [,,]. The AC component is helpful in determining the FHR as the arterial blood volume is synchronous with the heartbeat, but the signal obtained from the AC component is exceedingly small in range due to noises and artefacts [,]. The major challenge in determining fetal heart rate through PPG is the extraction of signals from noisy transducer data, which is mainly affected by acoustics, fetal and maternal contractions, fetal movements, and maternal breathing. The authors of [] introduced a PPG system for fetal heart rate monitoring involving a bandpass filter (BFP) in the range of 710–740 Hz from the abdomen of the mother, a cut-off frequency of the reference signal kept at 15 Hz, and the signal is down-sampled to 55 Hz, followed by a bandpass filter of 0.6–15 Hz to remove artifacts and unwanted noise in the received signal, deploying four phonogram sensors, as shown in a, and the PPG sensors for experiment validation, shown in b []. The FECG signals were captured invasively using PPG electrodes, and the experiment procedure and signal processing successfully removed the noise and maternal artefacts from the FECG signal [,]. 3.2. Cardiotocography (CTG)Cardiotocography (CTG) is a procedure for fetal heart rate detection introduced by Konrad Hammacher in 1970 [,,,]. CTG can be carried out both invasively and non-invasively, as shown in a [] and b []. In invasive CTG, an electrode is directly attached to the scalp of the fetus using a wire through the cervix. In contrast, in non-invasive CTG, electrodes are placed on the abdomen of pregnant women for the fetal heart rate detection. The signal quality of invasive CTG is more accurate but with less comfort and higher risk compared to non-invasive CTG [,]. Several studies concluded that long-term continuous monitoring using CTG resulted in discomfort to the patients. In addition, a study comprised of pregnant women at 20 weeks of pregnancy showed that the continuous fetal monitoring using CTG could result in an increase in the number of caesarean sections and misidentification of maternal heart rate [,]. 3.3. Doppler SoundThe Doppler principle is used in fetal heart rate monitoring by analyzing the mechanical activity of the heart, such as movement of valves of the heart of the fetus in the cardiac cycle [,]. The use of Doppler ultrasound to monitor the FHR, as shown in [], was proposed in the 1960s, but it is not suitable for continuous monitoring due to discomfort and irritation caused to the patients due to the gel and conduction paste used during the procedure. The procedure is non-invasive and deploys the ultrasound transducer placed on the maternal abdomen. The ultrasound with the frequency range of 1–2.3 MHz penetrates the tissue and the reflected sound wave generated by the internal structure of the body or fetus is received by the ultrasound transducer, which analyzes the fetal heart rate [,]. 3.4. Fetalelectrocardiography (FECG)For the fetus, fetal electrocardiography (FECG) helps to analyze FHR and health conditions because the heart of the fetus is the first organ to develop during the first 3–4 weeks of pregnancy. To determine FHR of the fetus, several fetal monitoring techniques, both invasive and non-invasive, are used. However, considering the comfort of the patient, a non-invasive process for FECG is usually preferred [,,,,]. In [], Clifford et al. analyzed and evaluated the FECG device’s accuracy in the context of fetal scalp electrodes (FSE) by comparing the results from the experiment. Thirty-two pregnant women were involved for data recording and the electrode placement was achieved following the configuration shown in . The signal quality varied according to fetal positioning. However, the results of the study depicted that an average correlation of 0.96 was achieved in comparison to results obtained using invasive fetal scalp electrodes (FSE). In [], the authors used a commercially available FECG device AN24 to continuously monitor the fetus and to determine the fetus health. Some of the commercially available NIFECG devices are shown in . To understand the importance of electrode placement, a study was non-invasively conducted using the Monica AN24 Monitor with five electrodes [,,,,]. It was observed that the non-invasive FECG was a preferred method to provide comfort to pregnant women in comparison to invasive FECG [,,]. However, the results indicated that the signal quality of the FECG data obtained was affected by maternal cardiograph (MECG) artefacts and noise, but the FECG signal can be extracted after applying a set of filters [,,,]. In [], a study was conducted using three pairs of electrodes which were placed on the abdomen of pregnant women. Complex continuous wavelet transform (CCWT) was deployed for the extraction of the FECG signal, using a four-stage procedure, as shown in . In the first stage, the signals coming from the three pairs of electrodes were averaged, followed by stage two comprising of CCWT and MECG detection. The detection and extraction of FECG was carried out in stage three, while stage four focused on analyzing the fetal heart rate (FHR). Furthermore, a method to extract FECG from the MECG using a multivariate singular spectrum analysis (MSSA) was used, comprising of two stages known as decomposition and reconstruction. This technique helped the researchers in detecting the FHR and separating the unwanted noise both in stationary and non-stationary signals. The main advantage of FECG monitoring is that it can be used remotely, in a non-clinical environment with high simplicity [,]. 4. Importance of Electrode Configurations for FECG Measurement4.1. Electrode Configurationsshows the comparison of electrode placement configurations over the maternal abdomen to monitor the FECG non-invasively. Comparisons have been made based on the number of electrodes placed on the maternal abdomen, and the filter parameter design used for pre-processing, such as bandwidth (BW), sampling frequency (Fs), resolution (R) of the A/D converter, and the gain (G). In , the comparison of different electrode placements is listed, which can further be divided into three different ranges, as listed in []. In terms of detection accuracy of FHR, it was noticed from that 97.47% was achieved with a four-electrode configuration through a three-step method, including time frequency analysis, complex wavelet, and Heuristic algorithm, at a sampling frequency of 300 Hz, resolution of 12 bits, with a gain of 7800. An accuracy of 91% was obtained with 8-electrode and 32-electrode configurations at a sampling frequency of 1 KHz. Additionally, from , comparing the sequential method and liner regression method using 12–16 electrodes, an accuracy of 85% was achieved in FHR monitoring. The accuracy of the method used for NIFECG monitoring to determine the fetal heart rate is entirely dependent on the number of electrodes used for monitoring, placement of electrodes, gestation week, and parameters such as sampling frequency, resolution bits, and the gain. Furthermore, in a long-term monitoring, use of the conventional hydrogel electrodes would also significantly affect the accuracy since the hydrogel electrodes would dry out over time, thus affecting skin-electrode impedance. 4.2. Electrode TypesIn FHR monitoring, the hydrogel electrodes improve ion conductivity and provide impedance matching between the skin and electrodes, thus minimizing noises and improving signal quality. However, hydrogel electrodes degrade and collect hair and dirt in addition to the possibility of causing skin irritation whilst being used, so they must be frequently replaced [,,,]. Moreover, the hydrogel layer on the electrodes tends to dry out over time so the long-term monitoring capability to monitor fetal heart rate will be compromised [,]. In view of the shortcomings of hydrogel electrodes in FHR monitoring, the smart-based electrodes have attracted more attention [,,]. Smart textiles exploit the universality of textiles which cover all types of woven, nonwoven, and knitted materials/fabrics. In recent years, the interest in smart textiles as tools to continuously monitor physiological signals, such as ECG, has increased due to the high comfort and portability, unlike traditional monitoring systems using hydrogel electrodes which could create skin irritation [,]. Conventional textile manufacturing methods have been used to fabricate e-textile electrodes. An example shown in a is the smart textile electrodes made through sewing conductive yarn to form electrodes. These electrodes are highly stretchable and flexible due to the nature of interlocking stitching patterns. Gold- or silver-coated yarn [] as well as stainless yarn [] are commonly used due to their high conductivity and the fact that they are readily available in the market []. However, the drawback is to build up a firm contact between skin and electrode surface without applying too much compression force through a strap. In contrast, printing techniques (e.g., screen printing) have also been adapted to fabricate electrodes on textiles. The carbon-based silicone is commonly used as an interface between skin and conductive layer to enhance the skin impedance matching and to provide a solid/stable contact, thus improving the ECG signal quality and minimizing the noise. An example of screen-printed ECG electrodes is shown in b, where carbon-loaded silicone is printed directly onto textile where it is needed to form the electrodes. These printed electrodes provide a higher degree of flexibility in terms of mass production, customization, impedance matching, and noise reduction. Vojtech et al. developed a three-electrode ECG monitoring system using prefabricated conductive textile [,,]. In comparison to conductive textile or knitting, sewing enable enhanced freedom because of the broad range of patterns that can be used and the ability to overlap stitches to create a denser patch of conductivity within the fabric []. Kannaian et al. deployed sewing and embroidery to integrate silver-coated threads into fabrics to achieve electrodes for a textile-based ECG monitoring system []. There are several methods available to be employed to adhere the conductive substance to the chosen substrate: dip and dry, sputtering, screen printing, chemical etching, stencil printing, and permeation [,]. The electrode type and method deployed for ECG monitoring depend on the properties of the conductive substance and the substrate. However, the screen printing can produce higher printing volume with fewer printing cycles to achieve a stable conductive pattern on e-textile surfaces and is also a standard mass production method used in the textile industry. 4.3. Current ECG Monitoring Development with Smart Textile ElectrodesTraditionally, ECG monitoring relies upon adhesive hydrogel electrodes. There are some key challenges that arise with this type of electrode including discomfort to patients due to skin irritation caused by hydrogels [,], difficult positioning when more electrodes are needed, and less accurate signal quality over longer period due to the degradation of hydrogel []. Over the past few years, novel concepts of using smart textile electrodes for monitoring ECG electrodes have emerged. Smart textiles-based electrodes are preferred for ECG monitoring as they can be deployed for longer term monitoring easily without any risk of hydrogel degradation and provide enhanced comfort to patients due to no skin irritation [,,]. Some examples of current development in smart textile ECG electrodes are summarized in . With the increase in cardiovascular diseases, there has been a growing interest in developing wearable devices, specifically smart textiles for ECG monitoring, that can continuously monitor cardiac activity without causing discomfort to patients []. A smart textile-based T-shirt achieved by knitting and embroidering stainless steel yarns on nylon fabric was deployed for long-term ECG monitoring, thus providing no skin irritation to patients, and enhancing the comfort to patients [,]. The authors of [,] used the woven and screen-printed smart textile electrodes for ECG monitoring. The authors of [] achieved a silver chloride electrode using electroless plating for the ECG monitoring. However, the use of smart textile electrodes in FECG and NIFECG has yet to be reported due to the following barriers: (a) the optimized number of electrodes required for fetal heart rate monitoring needs to be investigated, and (b) the signal quality of FECG needs to be improved due to the small amplitude compared with MECG. The deployment of smart textile electrodes in non-invasive fetal electrocardiography (NIFECG) for fetal heart rate (FHR) monitoring will revolutionize the healthcare monitoring in a way that smart textile-based electrodes would provide enhanced comfort to patients and no skin irritation during long-term monitoring. 5. ConclusionsThis paper provided a review of monitoring techniques including CTG, PPG, and Doppler sound, with the emphasis on fetal electrocardiogram (FECG), to detect fetal heart rate to determine the well-being and growth of the fetus. The importance of non-invasive FECG in contrast to invasive FECG in terms of comfort to patients was mentioned and highlighted in this paper. The different electrode configurations used in NIFECG monitoring were also discussed. It was shown that NIFFECG with fewer electrodes is more suitable for home use environments because the setup requires minimum preparation time, providing the essential FECG information and enhancing the comfort to the patients. One of the key drawbacks of current NIFECG is the use of hydrogel electrodes, which tend to degrade over time. The positioning of these electrodes may also increase the complexity for being used at home by pregnant women. These drawbacks could be overcome by the introduction of smart textile-based electrodes, which are realized using either conventional textile manufacturing methods or printing. These electrodes do not need the assistance of a hydrogel layer to provide adhesion. Instead, the garment on which the electrodes are formed provides contraction to attach the electrodes against the skin. In addition, these electrodes are realized on the correct position and therefore the complex setup process is minimized. It is suggested that future research could focus on improving the contact between smart textile electrodes and skin. This is of importance since the quality of the FECG signal is an indicator of the well-being of the fetus to diagnose any chronic diseases at an early stage of pregnancy, and thus to help in taking the essential preventive and precautionary steps on time. Moreover, electrode number and positioning need to be investigated in the context of smart textiles to provide a compromise between wearability, useability, washability, and signal quality, which is a future research direction in NIFECG monitoring using smart textile electrodes. Therefore, the deployment of smart textile electrodes in NIFECG monitoring will play a crucial role in long-term monitoring and comfort to patients. It is envisioned that the future perspective of smart textiles NIFECG in medical diagnosis will not be limited for the personal use because the device is believed to benefit the patients by carrying out the measurement either at hospitals by doctors or at home by themselves. There has been an ever-increasing utilization of cloud-based computing and Internet of things (IoT). Smart textile NIFECG should be light-weight and low-cost, providing data security and enhancing data transmission rate. Through cloud computing, the smart textile-based NIFECG measurement could be wirelessly connected to other medical IoT devices or a centralized hub, enabling accessing the essential health information from different locations. G.A. wrote the paper; Y.W. helped with revision; Both G.A. and Y.W. contributed to editing the paper. All authors have read and agreed to the published version of the manuscript. This research was funded by Nottingham Trent University strategic research theme, Medical Technologies and Advanced Materials. Not applicable. Not applicable. Not applicable. The authors declare no conflict of interest. Figure 1. Key features of FECG [] (Reprinted with permission from ref [] Radek Martinek (2012)). Figure 1. Key features of FECG [] (Reprinted with permission from ref [] Radek Martinek (2012)). Figure 2. The example of FECG embedded within the MECG signal [] (Reprinted with permission from ref [] Radek Martinek (2012)). Figure 2. The example of FECG embedded within the MECG signal [] (Reprinted with permission from ref [] Radek Martinek (2012)). Figure 3. PPG signal comprising of AC and DC components [] (Reprinted with permission from ref [] Javier Pérez Contonente). Figure 3. PPG signal comprising of AC and DC components [] (Reprinted with permission from ref [] Javier Pérez Contonente). Figure 4. (a) A schematic diagram showing the locations of phonogram sensors. Ch1, Ch2, Ch3, and Ch4 are four phonogram sensors. (b) Locations of phonocardiogram sensors and fetal ECG electrodes for the cross-validation experiment [] (Reprinted with permission from ref. [] (2018, CC BY 4.0)). Figure 4. (a) A schematic diagram showing the locations of phonogram sensors. Ch1, Ch2, Ch3, and Ch4 are four phonogram sensors. (b) Locations of phonocardiogram sensors and fetal ECG electrodes for the cross-validation experiment [] (Reprinted with permission from ref. [] (2018, CC BY 4.0)). Figure 5. (a) Non-invasive FECG measurement. (b) Invasive FECG measurement [] (Reprinted with permission from Radek Martinek (2012)). Figure 5. (a) Non-invasive FECG measurement. (b) Invasive FECG measurement [] (Reprinted with permission from Radek Martinek (2012)). Figure 6. An illustration of the Doppler sound procedure for FHR monitoring. Figure 6. An illustration of the Doppler sound procedure for FHR monitoring. Figure 7. Electrode placement for FECG. Figure 7. Electrode placement for FECG. Figure 8. Examples of CE/FDA-certified commercially available NIFECG-based devices []. (a) Monica AN24, (b) Monica Novii Wireless Patch System, (c) MERIDIAN M110 Fetal Monitoring System, (d) PUREtrace, (e) Nemo Fetal Monitoring System (Reprinted with permission from Radek Martinek (2019) (2019, Creative Commons License)). Figure 8. Examples of CE/FDA-certified commercially available NIFECG-based devices []. (a) Monica AN24, (b) Monica Novii Wireless Patch System, (c) MERIDIAN M110 Fetal Monitoring System, (d) PUREtrace, (e) Nemo Fetal Monitoring System (Reprinted with permission from Radek Martinek (2019) (2019, Creative Commons License)). Figure 9. The proposed 4-stage fetal heart rate (FHR) extraction method []. Figure 9. The proposed 4-stage fetal heart rate (FHR) extraction method []. Figure 10. (a) Sewn ECG electrode; (b) screen printed ECG electrode. (Reprinted with permission from ref [] Hasan, Muhammad (2009)). Figure 10. (a) Sewn ECG electrode; (b) screen printed ECG electrode. (Reprinted with permission from ref [] Hasan, Muhammad (2009)). Table 1. Comparison of different electrode placement for FECG monitoring. Table 1. Comparison of different electrode placement for FECG monitoring. No.AuthorNumber of Electrodes UsedElectrodes PlacementParameters’ SpecificationNumber of Participants and Time of Data Recording (s)AccuracyNumber of Gestation WeeksProposed Method for Extraction of FECG1.Chia et al., 2005 []3Equilateral triangle formation of three electrodes on the abdomen of pregnant women.N/AParticipants = 100Recording = 10 minSuccess rates for detecting the P, QRS, and T waves were 74.6%, 91.0%, and 79.3%, respectively>18 weeksCancellation of maternal template in 1st and 2nd derivative of abdominal signals2.Bergveld et al., 1986 []4Bandwidth = 0.2 to 120 HzParticipants = 37-Between 20 and 37 weeks-3.Algunaidi et al., 2011 []4Sampling Frequency = 256 Hz Resolution = 12 bitsParticipants = 30 Recording = 60 s-Between 36 and 38 weeksPeak detection Algorithm4.Karvounis et al., 2007 []4Sampling Frequency = 300 Hz Resolution = 12 bits Gain = 7800Two scenarios were used: 8 Participants and recording of 60 s was performed. 5 Participants and recording of 15 min each was performed.97.47%20–41 weeks3-stage method: time frequency analysis, complex wavelet, and Heuristic algorithm5.Emad. A. Ibrahim [].4N/AN/A60%34 weeksFetal heart rates (FHR) extracted from fetal phonocardiography (FPCG)6.Graatsma et al., 2008 []5-Bandwidth = 1–70 Hz Sampling frequency = 300 HzParticipants = 150 Time of recording = 15 h-Between 15 and 24 weeks-7.Rooijakkers et al., 2014 []6--Participants = 5 Recording = 20 min each-39 weeks-8.Vullings et al., 2009 []8Sampling frequency = 1 kHz Gain = 500Participants = 7 Recording = 10 min91%37–41 weeksWeighted Averaging of MECG segments (WAMES)9.Rooijakkers et al., 2012 []8Sampling Frequency = 1 kHz-91%40 weeks during laborPeak detection algorithm10.Andreotti et al., 2014 []8--Participants = 10 Recording = 20 min90%20–28 weeks-11.Zhang et al., 2014 []10--Participants = 78 Recording = 24 s each-3rd trimesterAdaptive R-wave detection algorithm12.Martens et al., 2007 []13Gain = 20-85%9 weeks to laborSequential estimation method13.Taylor et al., 2003 []12–16 electrodesSampling Frequency = 512 HzParticipants = 241 Recording = 25085%Between 15 and 33 weeksLinear regression to analyze QRS intervals14.Oostendorp et al.,1989 []32Sampling Frequency = 500 HzParticipants = 6 Recordings = 37-Between 20 and 40 weeksHomogeneous volume conduction model15.Clifford et al., 2011 []32-Sampling Frequency = 1 kHz-91.2%Between 35 and 41 weeks- Table 2. Different groups of electrode placement for NIFECG. Table 2. Different groups of electrode placement for NIFECG. No. of ElectrodesDiscussionReferenceGroup 1: range of electrodes between 1 and 4Advantages: For NIFECG monitoring, the electrodes are placed on the abdomen of pregnant women. Hence, less are used for fetus monitoring, resulting in a simple procedure without any discomfort to pregnant women.Disadvantages: The data recorded does not provide detailed information about the growth of the fetus.[,,,,,,,,,]Group 2, comprises a range between 10 and 20 electrodes.Advantages: It is evidenced that the more electrodes placed on the abdomen of pregnant women, the more comprehensive information can be gained about the fetus, thus helping in analyzing the well-being of the fetus efficiently and effectively. Disadvantages: Discomfort among the pregnant women due to several electrode placements on the abdomen of pregnant women.[,]Group 3, comprises a range of more than 20 electrodesAdvantages: Provides the detailed information about the growth of the fetus. Disadvantages: The deployment of 20 or more electrodes for FHR monitoring involves a complex setup procedure in addition to being expensive. Furthermore, results in skin irritation and severe discomfort to pregnant women due to gel used in setting up the electrodes to establish effective electrode configuration.[,] Table 3. Some examples of smart textile ECG research. Table 3. Some examples of smart textile ECG research. No.MethodMaterialSystem IntegrationReference1.KnittingStainless steelT-shirt[]2.Knitting and EmbroideryStainless steel filament, nylon fabricT-shirt[]3.Weaving and KnittingSilver yarnsChest band[]4.Screen printingSilver inkChest band[]5.Electroless plattingSilver chlorideSmart garment[]Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Share and CiteMDPI and ACS Style Aggarwal, G.; Wei, Y. Non-Invasive Fetal Electrocardiogram Monitoring Techniques: Potential and Future Research Opportunities in Smart Textiles. Signals 2021, 2, 392-412. https://doi.org/10.3390/signals2030025 AMA Style Aggarwal G, Wei Y. Non-Invasive Fetal Electrocardiogram Monitoring Techniques: Potential and Future Research Opportunities in Smart Textiles. Signals. 2021; 2(3):392-412. https://doi.org/10.3390/signals2030025 Chicago/Turabian StyleAggarwal, Geetika, and Yang Wei. 2021. "Non-Invasive Fetal Electrocardiogram Monitoring Techniques: Potential and Future Research Opportunities in Smart Textiles" Signals 2, no. 3: 392-412. https://doi.org/10.3390/signals2030025 What instrument is used to measure the fetal heart rate?A fetoscope (a type of stethoscope) is the most basic type of external monitor. Another type of monitor is a hand-held electronic Doppler ultrasound device. These methods are often used during prenatal visits to count the fetal heart rate.
What machine is used for NST?We use a machine known as a fetal monitor to do a non-stress test. A non-stress test (NST) looks at your baby's heart rate over time (usually 20 to 30 minutes, but sometimes up to an hour). The monitor has two sensors that are placed on your belly with two belts that go around your waist.
|